F010 Safe area


The F010 is a local indicator with large 26mm (1″) high digits which displays the actual flow rate. The measuring and time unit to be displayed below the flow rate are simply selected through an alphanumeric configuration menu. No adhesive labels have to be put on the outside of the enclosure: a weatherproof and user-friendly solution! The configuration of K-factors or Span and number of decimals is done through software functions, without any sensitive DIP-switches or trimmers.

Share as :

Product specifications

  • Signal Inputs

    • Flowmeter Inputs

      • Pulse type inputs:
        Reed-switch, NAMUR, NPN/PNP pulse, Sine wave (coil), active pulse signal.
      • (0)4 – 20mA.
      • 0 – 10V DC.
  • Signal Outputs

    • Pulse outputs

      • None.
    • Alarm outputs

      • None.
    • Analog outputs

      • None.
  • Supply

    • Power Supply

      • Long life Lithium battery.
      • 4 – 20mA, input Loop-powered.
      • 8 – 24V AC/DC.
      • 115 – 230V AC.
      • Basic: 8 – 30V DC.
    • Sensor Supply

      • 3.2, 8.2, 12, 24V DC.
  • Hazardous Area

    • Intrinsically Safe

      • ATEX:
        Gas: II 1 G Ex ia IIC T4 Ga
        Dust: II 1 D Ex ia IIIC T200 100 °C Da
      • IECEx:
        Gas: Ex ia IIC T4 Ga
        Dust: Ex ia IIIC T200 100 °C Da
      • CSA & FM:
        I.S. Class I/II/III, Div 1, Grp A…G, T4
        Class I, Zone 0, AEx ia IIC T4 Ga
        Note: Extended aluminum enclosures not available with CSA/FM approval.
    • Explosion Proof

      • ATEX/IECEx:
        Gas: II 2 G Ex db IIB+H2 T5 Gb
        Dust: II 2 D Ex tb IIIC T80°C Db
  • Communication

    • Modbus communication available on F1-Series products.

    • HART communication is available with the F018 Flow rate Monitor / Totalizer.